Brick converters — quarter, half, full — exist so that a board designed once can be re-powered for decades. The footprint is standard. The trap is assuming the rest is.
Start with the footprint, then stop trusting it
A quarter-brick from any serious maker lands on the same industry footprint — in our range that is the MDQ family, 50–300 W. Half-bricks (MDH, 75–400 W) and full bricks (MDF, 500–600 W) follow the same idea at higher power, and the eighth-brick (MDE) covers compact builds. Footprint compatibility gets the module onto your board. It says nothing about whether it will run there.
The four checks that decide it
Pin-out. Pin functions and polarity differ between makers on the same footprint. Compare the two datasheets pin by pin — this is the check that saves boards.
Input window. Match the real bus, not the nominal one. Many of our brick series take 43–160 V or 66–160 V — written for the railway 110 V bus, and forgiving of everything below it.
Efficiency and heat. Catalogue efficiency across the brick families runs mostly 87–92%. At 300 W, the difference between 87% and 92% is roughly 19 W of heat your baseplate has to move. Derate for your actual ambient, not the catalogue's.
Control pins. Enable polarity, trim range and remote-sense behaviour are the quiet differences. List them against your board before the first sample, not after.
Where the MDH-C fits
The MDH-C half-brick line is the catalogue's drop-in answer for Japanese half-bricks — the replacement work this range is built around. Send us the model you are replacing; we verify pin-out against both datasheets and quote the match, with dimension drawings from the module catalogue for the fit check.